Hydrostatic Level measurement Deltapilot FMB53

Accuracy
• Standard 0.2%
• Optional 0.1%
Process temperature
• PE cable: -10°C…70°C / 14°F…158°F
• FEP cable: -10°C…80°C / 14°F…176°F
Pressure measuring range
• 100mbar...10bar
• (1.5psi...150psi)
Process pressure absolute / max. overpressure limit
• 40 bar (600 psi)


Deltabar PMD55B - differential pressure transmitter

Process temperature
• -40°C…+110°C (-40°F... + 230°F)
Pressure measuring range
• 30 mbar.... 40 bar (0.45 psi... 600 psi)
Main wetted parts
• 316L, AlloyC
Material process membrane
• 316L, AlloyC
Measuring cell
• 30 mbar...40 bar
• (0.45 psi...600 psi)

Radar measurement-Micropilot FMR60

Accuracy
• +/- 1 mm (0.04 in)
Process temperature
• -40…+130 °C
• (-40…+266 °F)
Process pressure absolute / max. overpressure limit
• Vacuum …16 bar
• (Vacuum … 232 psi)
Max. measurement distance
• 50 m (164 ft)


Proline Promag P 300 - Electromagnetic flowmeter

Max. measurement error
• Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
• Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
• 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
Medium temperature range
• Liner material PFA: –20 to +150 °C (–4 to +302 °F)
• Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
• Liner material PTFE: –40 to +130 °C (–40 to +266 °F)